Product Name£ºBNT-2000B
Product Model£º¡Ü1000VA
Production brand£ºLencen Medical
   Product details
STANDARD COMPOSITION:
Temperature Control Mode: per-heating control, servo control & manual control;
Instant Parameter Display: Set temp, skin temp, heat power rate;
Built- in APGAR Timer and >37¡æ preset function
Audible/ Visual Alarms: temp deviation, Sensor failure, power failure, temp override;
Tilting Bed and Rotary Radiant Head;
X-ray Cassette Tray under infant bed, examination light of high illuminance ;
Use anti-blast quartz infrared tube as radiant hearing source.


Optional Deice (At Buyers¡¯ Selection):
XYQ1003 Intra Low-pressure suction.

TD1001 Phototherapy Lights 
Mounting beside radiant heard of infant Radiant Warmer.
  BNT--1000 BNT--2000 BNT-2000(B)
Operational condition:      
Environment temperature +18¡æ--+30¡æ +18¡æ--+30¡æ +18¡æ--+30¡æ
Environment relative humidity 30%---75% 30%---75% 30%---75%
Environment air velocity of flow <0.3m/s <0.3m/s <0.3m/s
Power requirement ¡Ü1000VA ¡Ü1000VA ¡Ü1000VA
Temperature control mode Auto Pre-heat, auto and manual Pre-heat, auto and manual
Temperature control range 25¡æ--37¡æ 25¡æ--37¡æ 25¡æ--37¡æ
Temperature override mode to ----- 38¡æ 38¡æ
Temperature sensor accuracy ¡Ü0.3¡æ ¡Ü0.3¡æ ¡Ü0.3¡æ
Mattress temperature uniformity ¡Ü2.0¡æ ¡Ü2.0¡æ ¡Ü2.0¡æ
Temperature rise time ¡Ü45 min ¡Ü45 min ¡Ü45 min
Radiant box horizon angle adjust range 0--¡À90¡ãstep-less 0--¡À90¡ãstep-less 0--¡À90¡ãstep-less
Mattress Tray Size 68*56cm 68*56cm 68*56cm
Mattress tilt adjust range 0--¡À10¡ãstep-less 0--¡À10¡ãstep-less 0--¡À10¡ãstep-less
Mattress tray Max. load 10kg 10kg 10kg
Transfusion pole Max .load 2kg 2kg 2kg
Shelf Max. load 2kg 2kg 2kg
X-ray shelf Yes Yes Yes
RS-232 Connector ---- Yes Yes
Mattress to Radiant box 81cm 81cm 81cm
Heater infrared wave length 1--3¦Ìm 1--3¦Ìm 1--3¦Ìm
APGAR Timer ----- Yes Yes
Alarms      
Power failure alarm Yes Yes Yes
Sensor failure alarm Yes Yes Yes
Temperature deviation alarm ¡À1.0¡æ ¡À1.0¡æ ¡À1.0¡æ
Over temperature alarm ¡Ü38.0¡æ ¡Ü38.0¡æ, ¡Ü39.0¡æ ¡Ü38.0¡æ, ¡Ü39.0¡æ
       
Low-pressure suction ------ ------ Yes
Pressure adjust range ------ ----- 0-22Kp(0-165mmHg)
Operating noise ----- ----- ¡Ü55 dB
White Phototherapy light ------- ------- 1 set
7L Oxygen cylinder (with oxygen manometer & oxygen flow meter ) ------- -------- 2 sets
Neonate resuscitation bag ------ ----- 1 set
Packing size 110*90*110cm 110*90*110cm 110*90*110cm
Net weight 85 kg 85 kg 85 kg
Gross weight 115 kg 115 kg 125 kg