Products
B-1000


Click to see big picture
Product Name£ºB-1000
Product Model£ºB-1000
Production brand£ºLencen Medical
   Product details
Standard Composition: Servo Control Mode: air temperature, skin temperature, display humidity;
Instant Parameter Displaying: set temp, air temp , skin temp , internal humidity , heat power rate;
Audible & Visual Alarms: power failure, sensor failure, higher & lower temp, air & skin temp override, fan failure, system failure;
>37¡ãC£¬ Preset Mode: power failure reset memory , alarm silence, keypad lock , self-test function;
Hood with dual slop; 6 hand ¨C ports; left & right cabinets, rail;
RS-232 Output Connector (use for network system).

Optional Devices (At Buyers¡¯Selection):

  Optional Devices (At Buyers¡¯ Selection):
YEC¡ª1002 Infant scale , to weigh up infant weight.

  YC Stepless Adjusting Infant Bed. Adjust tilt +10¡ã.

  GL Blue Light Phototherapy Unit, LED Digital Timer, Display therapy time & total time.

  SC Double Wall Canopy
  B--3000 B--2000 B-1000 B-800
Mattress to Hood 45mm 450mm 450mm 410mm
Observation side of hood Two incline Two incline Two incline Two incline
Operate port 6(2 Iris ports) 6(2 Iris ports) 6(2 Iris ports) 6(2 Iris ports)
Tubing grommets 4 4 4 4
Front access panel 826*310mm 826*310mm 826*310mm 826*310mm
Mattress Tray Size 630*630mm 630*630mm 630*630mm 630*630mm
Technical Specifications        
Power requirement ¡Ü400VA ¡Ü400VA ¡Ü400VA ¡Ü400VA
Temperature control mode Air and skin servo control Air and skin servo control Air servo control Air servo control
Air Temp Control Range 20¡æ--37¡æ 20¡æ--37¡æ 20¡æ--37¡æ 20¡æ--37¡æ
Temperature override mode to 20¡æ--39¡æ 20¡æ--39¡æ 20¡æ--39¡æ ------
Sin Temp Control Range 20¡æ--37¡æ 20¡æ--37¡æ ----- -------
Temperature override mode to 30¡æ--38¡æ 30¡æ--38¡æ ------ --------
Skin temp sensor accuracy ¡Ü0.3¡æ ¡Ü0.3¡æ ------ -------
Humidity display range 5%--99% ----- ------- --------
Temperature fluctuation ¡Ü0.5¡æ ¡Ü0.5¡æ ¡Ü0.5¡æ ¡Ü0.5¡æ
Mattress temperature uniformity ¡Ü0.8¡æ ¡Ü0.8¡æ ¡Ü0.8¡æ ¡Ü0.8¡æ
Temperature rise time ¡Ü30 min ¡Ü30 min ¡Ü30 min ¡Ü30 min
Noise level within hood environment ¡Ü55dB ¡Ü55dB ¡Ü55dB ¡Ü55dB
Alarms        
Power failure alarm Yes Yes Yes Yes
Fan failure alarm Yes Yes Yes Yes
Sensor failure alarm Yes Yes Yes Yes
High air temperature alarm +1.5¡æ +1.5¡æ +1.5¡æ +1.5¡æ
Low air temperature alarm -2.5¡æ -2.5¡æ -2.5¡æ -2.5¡æ
High skin temperature alarm +1.0¡æ +1.0¡æ ----- ------
Low skin temperature alarm -1.0¡æ -1.0¡æ ----- -----
Over air temperature alarm ¡Ü38.0¡æ;
¡Ü40.0¡æ
¡Ü38.0¡æ;
¡Ü40.0¡æ
¡Ü38.0¡æ;
¡Ü40.0¡æ
¡Ü38.0¡æ;
Over skin temperature alarm ¡Ü38.0¡æ;
¡Ü39.0¡æ
¡Ü38.0¡æ;
¡Ü39.0¡æ
¡Ü38.0¡æ;
¡Ü39.0¡æ
-----
System failure alarm Yes Yes Yes Yes
Alarm silence function Yes Yes Yes Yes
Operational condition        
Environment temperature +20¡æ-+30¡æ +20¡æ-+30¡æ +20¡æ-+30¡æ +20¡æ-+30¡æ
Environment relative humidity 5%---99% 5%---99% 5%---99% 5%---99%
Environment air velocity of flow <0.3m/s <0.3m/s <0.3m/s <0.3m/s
others        
RS¡ª232 Connector Yes Yes Yes Yes
Rail Yes Yes Yes Yes
Infant bed tilt adjusting ¡À10¡ãstep-less ¡À10¡ãstep-less ¡À10¡ãstep-less -----
Mattress tray Max. load 10kg 10kg 10kg 10kg
Transfusion pole Max. load 2kg 2kg 2kg 2kg
Cabinet Max. load 6kg 10kg 10kg -----
Packing size (2cartons) 100*58*80cm 100*58*80cm 100*58*80cm 100*58*80cm
Gross Weight 120kg 120kg 120kg 120kg

Copyright (C) Linkgold(LENCEN MEDICAL) Medical Instrument Co., Ltd.